주요특징
M9287 (PROFINET NETWORK ADAPTER) | |
Adapter Type |
Slave node (Profinet), Single |
Protocol | Profinet, Modbus RTU |
Max. Expansion Module | 32 slots |
Max. Data Size(Input + Output) | Max 1440 bytes |
Max Length Bus Line | Up to 100m from Ethernet Hub/Switch with twisted CAT5 UTP/STP |
Max. Nodes | Limited by Profinet Specification |
Baud Rate | 100Mbps, Auto-negotiation, Full duplex |
Interface Connector | RJ-45 socket * 2pcs |
IP-Address Setup | Via Master Device Software |
Max. Parameter Size | 2048 Bytes (ex : 1 slot = 64 Byte + I/O Parameter Size(Dword size)) |
Serial Port | RS232 for MODBUS/RTU, Touch Pannel or IOGuide |
Serial Configuration (RS232) | When DIP Switch 1 to 8 setting is 254 or 255 (Using only Internet Explorer / recommended version 11 ) |
Serial Port | Node : 1 (Fixed) Baud Rate : 115200 (Fixed) Data bit : 8 (Fixed) Parity bit : No parity (Fixed) Stop bit : 1 (Fixed) |
Indicator | 4 LEDs 1 Green/Red, Module Status (MOD) 1 Green, Physical Connection (NET) 1 Green/RED, Network Error (ERROR) 1 Green/Red, Expansion I/O Module Status (IOS) 2 LEDs (each RJ45 Connector) 1 Yellow, Link/Active 1 Green, Not used |
Module Location | Starter module left side of M-Series system |
General specification (Supplied by M7001) | |
UL System Power | Supply voltage : 24Vdc nominal, Class 2 |
System Power | Supply voltage : 24Vdc nominal Supply voltage range : 15~28.8Vdc Protection : Output current limit, Reverse polarity protection |
Power Dissipation | 85mA typical @ 24Vdc |
Current for I/O Module | 2.0A @ 5Vdc (If except for NA, current for I/O module is about 1.5A) |
Isolation | System power to internal logic : Non-isolation System power I/O driver : Isolation |
UL Field Power | Supply voltage : 24Vdc nominal, Class 2 |
Field Power | Supply voltage : 24Vdc typical (Max.28.8Vdc) * Field Power Range is different depending on IO Module series. Refer to IO Module`s Specification. |
Max. Current Field Power Contact | DC 10A Max |
Weight | 179g |
Module Size | 54mm x 110mm x 75mm |